Immitance Analyzer Broadband E7-29

new
Печать

Описание

  • Extended frequency range 50 kHz – 15 MHz
  • Base accuracy ± 0.2%
  • Measuring signal level 40 mV - 1 V rms
  • Offset voltage (0 - 40) V
  • Resolution resolution of the operating frequency 1 Hz
  • Graphical analysis of measured values in a given frequency range
  • USB 2.0 Interface
  • -100 C to 400 C; humidity 90% at 300 C
  • Dimensions, weight: 270х134х320 mm, 5 kg
  • Power supply ~ 230 V, 20 VА

The broadband E7-29 immitance analyzer is a precision instrument of accuracy class 0.2 with a wide range of operating frequencies. By technical parameters, it replaces most of the E7 class devices manufactured in the CIS countries.

E7-29 Broadband Immittance Analyzers are designed to measure the immitance parameters of radio electronic elements (ERE) in the frequency range from 50 kHz to 15 MHz.

Scope - scientific research, control of electrical parameters of electric energy devices at enterprises, in repair shops, scientific institutions.

The device measures the following immitance parameters:

Lp, Ls - inductance in a parallel, serial equivalent circuit;

Cp, Cs - capacity in a parallel, sequential equivalent circuit;

Rp, Rs - active resistance in a parallel, serial equivalent circuit;

X is the reactance in a series equivalent circuit;

G is the active conductivity in a parallel equivalent circuit;

B - reactive conductivity in a parallel equivalent circuit;

tg δ is the loss tangent (the designation D is allowed - loss factor);

Q - quality factor;

| Z | - integrated resistance module;

| Y | - module of complex conductivity;

φ is the angle of the phase shift of the complex resistance.

Objects of measurement: capacitors, inductors, transformers, resistors, relays, switches, diodes, cables, input resistances and capacities of oscilloscopes, voltmeters and other devices. With appropriate sensors, the device can measure various physical quantities.

The measuring ranges correspond to the values ​​indicated in the table.

Physical quantity

 

Measuring range

Rp, Rs, Х, |Z|

from 10 mOhms to 100 MOhms

G, В, |Y|

from 10 nCm (100 MOhms) to 100 Cm (10 MOhms)

Lp, Ls

from 10 nH  to 100 H;

Сp, Сs

from 0,001 pF to 100 mcF

D

from 1*10-4 to 9,9999*103

Q

from 1*10-4 to 9,9999*103

φ

from minus 1800 to plus 1800

      Note - Display format 5 decimal places.

 